Scenario: customer is using hp p6300 iscsi with firmware 11001000 and the svmotion fails.
error:
error:
2012-09-04T01:30:38.234Z| Worker#0| DISKLIB-VMFS
:Vmfs_MoveData : failed to move data (Device or resource busy:0x100009).
2012-09-04T01:30:38.240Z| Worker#0|
DISKLIB-LIB : DiskLibCopyDataInt: Failed to copy using vmkernel data mover; failing the copy
operation. Device or resource busy
2012-09-04T01:30:38.240Z| Worker#0|
DISKLIB-LIB : DiskLibCopyDataInt failed with Device or resource
busy.
2012-09-04T01:30:38.240Z| Worker#0| SVMotionMirroredMode:
noticed migration failure, backing out of disk copy.
VMware HCL says that the firmware compatible is
11000000 but not 11001000 yet.
resolution:
The problem turns out to be caused by an old iSCSI firmware
module. This seems to be incompatible with the latest firmware XCS
11001000.
Original version for iSCSI module was
3_2_2_6
New version is 3_2_2_9
Disable the VAAI from ESX(i) host and svmotion will work. upgrade the iscsi module, then enable the VAAI option again and the svmotion will still work.
No comments: